Title of article :
A HPLC-UV method for the determination of puerarin in rat plasma after intravenous administration of PEGylated puerarin conjugate
Author/Authors :
Liu، نويسنده , , Xinyi and Zhi، نويسنده , , Hongying and Du، نويسنده , , Feng and Ye، نويسنده , , Zuguang and Wang، نويسنده , , Naijie and Qin، نويسنده , , Wenjie and Li، نويسنده , , Jianrong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
A sensitive and reproducible HPLC method for quantitative determination of puerarin (PUE) in rat plasma was developed and validated using 4-hydroxybenzaldehyde as an internal standard. The separation of PUE was performed on a CAPCELL PAK C18 column by gradient elution with 0.2% aqueous phosphoric acid and acetonitrile as the mobile phase. The method was validated and found to be linear in the range of 80–12,000 ng/mL. The limit of quantification was 80 ng/mL based on 100 μL of plasma. The variations for intra- and inter-day precision were less than 8.3%, and the accuracy values were between 98% and 105.2%. The extraction recoveries were more than 85%. The method was successfully applied in the comparative study of pharmacokinetics of PEGylated puerarin (PEG-PUE) versus PUE in rats. Compared with PUE, PEG-PUE showed a 5.2-fold increase in half-life of PUE and a 4.7-fold increase in mean residence time. In addition, this method was also successfully applied to determine the low plasma concentration of PUE regenerated from PEG-PUE in vitro.
Keywords :
Puerarin , Rat plasma , HPLC-UV , Pharmacokinetics , PEGylated puerarin
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B