• Title of article

    Evaluation of freshness decay of minced beef stored in high-oxygen modified atmosphere packaged at different temperatures using NIR and MIR spectroscopy

  • Author/Authors

    Sinelli، نويسنده , , Nicoletta and Limbo، نويسنده , , Sara and Torri، نويسنده , , Luisa and Di Egidio، نويسنده , , Valentina and Casiraghi، نويسنده , , Ernestina، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    5
  • From page
    748
  • To page
    752
  • Abstract
    Meat freshness has been monitored by various microbiological, chemical and sensorial indices. However, these methods are slow and not suited to automation. Infrared spectroscopy is one of the most convenient analytical tools which could be used to monitor the evolution of food quality. The aim of this work was to investigate the ability of both NIR (Near Infrared) and MIR (Mid Infrared) spectroscopy to follow meat freshness decay. The minced beef was packaged in high-oxygen modified atmosphere (30% CO2 and 70% O2) and stored at three temperatures. Spectra were collected by Fourier-Transformation (FT)-NIR and FT-IR instruments. PCA, applied to the data, was able to discriminate samples on the basis of storage time and temperature. The modelling of PC scores versus time allowed the setting of the time of initial freshness decay for the samples (6–7 days at 4.3 °C, 2–3 days at 8.1 °C and less than 1 day at 15.5 °C).
  • Keywords
    freshness , Minced beef , NIR spectroscopy , MIR spectroscopy
  • Journal title
    Meat Science
  • Serial Year
    2010
  • Journal title
    Meat Science
  • Record number