• Title of article

    Behaviour of fire-exposed concrete-filled steel tubular beam columns repaired with CFRP wraps

  • Author/Authors

    Tao، نويسنده , , Zhong and Han، نويسنده , , Lin-Hai، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    14
  • From page
    63
  • To page
    76
  • Abstract
    This paper presents the test results of fire-exposed concrete-filled steel tubular (CFST) beam columns repaired by unidirectional carbon fibre reinforced polymer (CFRP) composites. Both circular and square specimens were tested to investigate the repair effects of CFRP composites on them. The test results showed that the load-bearing capacity of the fire-exposed CFST beam columns was enhanced by the CFRP jackets to some extent, while the influence of CFRP repair on stiffness was not apparent. The strength enhancement from CFRP confinement decreased with the increasing of eccentricity or slenderness ratio. Ductility enhancement was also observed except those axially loaded shorter specimens with rupture of CFRP jackets at the mid-height, occurred near the peak loads. However, the strengths of all repaired specimens have not been fully restored due to the long exposure time of them in fire. From the test results, it is recommended that, in repairing severely fire-damaged CFST members, slender members or those members subjected to comparatively large bending moments, other appropriate repair measures should be taken.
  • Keywords
    Beam columns , FRP , Fire-exposed , Post-fire , residual strength , Repair , Concrete-filled steel tubes (CFST)
  • Journal title
    Thin-Walled Structures
  • Serial Year
    2007
  • Journal title
    Thin-Walled Structures
  • Record number

    1492307