• Title of article

    Built-up battened columns under lateral cyclic loading

  • Author/Authors

    Sahoo، نويسنده , , Dipti R. and Rai، نويسنده , , Durgesh C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    11
  • From page
    552
  • To page
    562
  • Abstract
    Built-up members with battens designed for typical 2–2.5% of axial load may not behave satisfactorily in the presence of lateral seismic loads. Analytical evaluation of double-channel battened cantilever members designed as per the current practice, and subjected to constant axial compressive load and gradually increasing lateral load showed that the members failed to reach their expected flexural capacity due to lateral instability. The design of members was modified by changing the configuration of battens in the expected plastic-hinge region, i.e., reducing the spacing of battens in end panel by half, and designing battens for a shear demand due to moment capacity of section. The members with battens designed for moment capacity could able to reach the expected flexural strength. Five half-scale test specimens of battened members designed as per the current practice and improved design method were subjected to axial load and gradually increasing cyclic load. The specimens designed as per improved design method showed excellent performance in terms of lateral strength, lateral stiffness, moment rotation characteristics and energy dissipation capacity.
  • Keywords
    Column , Buckling , Battened , Seismic
  • Journal title
    Thin-Walled Structures
  • Serial Year
    2007
  • Journal title
    Thin-Walled Structures
  • Record number

    1492377