Title of article
Strength and ductility of stiffened thin-walled hollow steel structural stub columns filled with concrete
Author/Authors
Tao، نويسنده , , Zhong and Han، نويسنده , , Lin-Hai and Wang، نويسنده , , Dong-Ye، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
16
From page
1113
To page
1128
Abstract
It is generally expected that inner-welded longitudinal stiffeners can be used to improve the structural performance of thin-walled hollow steel structural stub columns filled with concrete. Thirty-six specimens, including 30 stiffened stub columns and six unstiffened ones, were tested to investigate the improvement of ductile behaviour of such stiffened composite stub columns with various methods. The involved methods include increasing stiffener height, increasing stiffener number on each tube face, using saw-shaped stiffeners, welding binding or anchor bars on stiffeners, and adding steel fibres to concrete. It has been found that adding steel fibres to concrete is the most effective method in enhancing the ductility capacity, while the construction cost and difficulty will not be increased significantly.
Keywords
Concrete-filled steel tube (CFST) , Thin-walled , Axial compression , Stub columns , stiffeners , Steel fibre reinforced concrete (SFRC) , Binding bars , Anchor bars , Local Buckling , ductility
Journal title
Thin-Walled Structures
Serial Year
2008
Journal title
Thin-Walled Structures
Record number
1492853
Link To Document