• Title of article

    Experimental investigation of built-up double-Z members in bending and compression

  • Author/Authors

    Georgieva، نويسنده , , Iveta and Schueremans، نويسنده , , Luc and Pyl، نويسنده , , Lincy and Vandewalle، نويسنده , , Lucie، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    10
  • From page
    48
  • To page
    57
  • Abstract
    Using the conventional cold-formed shapes in built-up assemblies (composed members, trusses, etc.) has allowed designers of light-steel framing to widen the applications of cold-formed steel (CFS) to structures of larger scale. Built-up elements, fastened by bolts, screws or welds are usually symmetrical, more stable and of higher capacity. However, they are not addressed in the various design codes for CFS structures. Additional flexibility is caused by slippage between the constituents of a composed member, especially if bolts are used as interconnectors and hole clearances are provided to ensure the ease of assembly. The paper presents experimental studies on the behaviour of double-Z built-up members (bolted). First, twelve members are tested in weak-axis bending, to evaluate the stiffness of the member for the axis of symmetry. Second, the overall behaviour is analysed in eight compression tests on slender members. The goal is to determine the actual failure mode and overall buckling capacity of these members.
  • Keywords
    Built-up sections , Light-steel framing , Full-scale experiments , distortional buckling , cold-formed steel
  • Journal title
    Thin-Walled Structures
  • Serial Year
    2012
  • Journal title
    Thin-Walled Structures
  • Record number

    1493431