• Title of article

    Experimental study on local buckling of axially compressed steel stub columns at elevated temperatures

  • Author/Authors

    Wang، نويسنده , , Weiyong and Kodur، نويسنده , , Venkatesh and Yang، نويسنده , , Xingcai and Li، نويسنده , , Guoqiang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    13
  • From page
    33
  • To page
    45
  • Abstract
    There are few design provisions in codes and standards on local buckling of steel columns under fire conditions. To examine the local stability of steel stub columns at elevated temperatures, 12 stub columns were tested under simultaneous application of load and fire conditions. The test variables included Grade (type) of steel, buckling resistance, temperature and load levels. During fire tests, cross sectional temperatures, axial displacement, buckling deflection, and local buckling failure modes of flange and web of stub columns were recorded at various temperatures. Data from the tests is utilized to evaluate buckling resistance of flange and web both at room and elevated temperatures by applying the ultimate strain method and curve inflexion point method. Results from fire tests are utilized to validate a finite element model developed for tracing local buckling of steel columns at elevated temperatures. Results from fire tests and finite element analysis show that failure mode of columns at room and elevated temperatures follow similar pattern but the load bearing capacity of Q460 steel columns degrade much more rapidly under fire conditions than that of Q235 steel columns. Further, Eurocode 3 provisions for local buckling produce non-conservative results in certain situations.
  • Keywords
    Local Buckling , fire tests , Temperature , Stub columns , Q460 steel
  • Journal title
    Thin-Walled Structures
  • Serial Year
    2014
  • Journal title
    Thin-Walled Structures
  • Record number

    1494321