Abstract :
In this paper the flow over regular arrangements of buildings with slanted roofs is numerically studied and its impact on pollutant dispersion is analyzed. By systematically varying the roof slope, we could identify the switching point between a one- and a two-vortex regime inside the street canyons between the buildings. In the one-vortex regime, the pollutant concentration in the street canyon is found to decrease with increasing roof slope, which is related to the rotational speed of the canyon vortex and the aerodynamic roughness felt by the fully-developed flow aloft the street canyons. In the two-vortex regime limited mixing occurs between both vortex cores, resulting in higher near-ground pollutant concentrations. Compared to the widely studied flat-roof case, slightly upward slanted roofs exhibit a lower aerodynamic roughness, yet yield similar air quality in the street canyon.
Keywords :
Boundary layer , dilution , aerodynamic roughness , Mesh sensitivity , Domain size sensitivity , Turbulent Schmidt number , Slanted roof , Vortex center , CFD , Air quality