Abstract
This article describes the possibilities of continuously measuring coal moisture in the boiler feeding circuit of a thermal power station so that the measurement can be used as a signal for the boiler combustion control system. To do so, in the first place, the point through which coal would be fed into the boiler was chosen. After studying the different parts of the circuit, the feeder was selected. Then, an installation was designed, at semi-industrial scale, faithfully reproducing the operation of a belt conveyor. In order to measure the moisture content, a microwave system was installed, and a large number of coal samples with different ranks and grain sizes was tested showing eventually the likelihood of the objective.
Keywords
Signal , Thermal power station , Coal moisture