Title of article
Ion chromatographic determination of lithium at trace level concentrations: Application to a tracer experiment in a high-mountain lake
Author/Authors
By U. NICKUS، نويسنده , , Ulrike and Thies، نويسنده , , Hansjِrg and Stemplinger، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
4
From page
201
To page
204
Abstract
The water residence time of a high-mountain seepage lake in the Austrian Alps was derived from the flushing rate of a tracer substance. A diluted lithium chloride solution was injected into the lake during holomictic conditions in order to favour the homogeneous distribution of the tracer. The exponential decline of the mass of lithium in the lake revealed a water residence time of 1.5 to 3 months for summer and almost no lake water exchange during winter. Lithium concentrations ranged from background values of 0.06 μg l−1 to about 3 μg l−1 immediately after the tracer injection. Lake water samples were analyzed with ion-exchange chromatography using a Dionex device with a CS 12A separation column. The method detection limit determined according to the definition of the US Envirinmental Protection Agency amounted to 0.009 μg l−1.
Keywords
lithium chloride , Metal cations
Journal title
Journal of Chromatography A
Serial Year
2001
Journal title
Journal of Chromatography A
Record number
1507979
Link To Document