Title of article
Micellar electrokinetic chromatography of polyamines and monoacetylpolyamines
Author/Authors
Taibi، نويسنده , , G and Schiavo، نويسنده , , M.R and Calanni Rindina، نويسنده , , P and Muratore، نويسنده , , R and Nicotra، نويسنده , , C.M.A، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
7
From page
323
To page
329
Abstract
A selective procedure for qualitative and quantitative analysis of ten polyamines by micellar electrokinetic chromatography (MEKC) was developed. Benzoylated polyamines and acetylpolyamines in micellar phase of SDS (10 mM) were separated at 25°C by 20 mM borate buffer pH 8.5, containing 8% ethanol, with an applied voltage of 25 kV (5 μA) and then detected at 198 nm. The experimental factors and operational parameters were optimized by performing analysis at different surfactant concentrations, pH, voltage and temperature with and without ethanol. The repeatibility of migration times and peak heights is a peculiarity of the method here described.
Keywords
polyamines , Monoacetylpolyamines
Journal title
Journal of Chromatography A
Serial Year
2001
Journal title
Journal of Chromatography A
Record number
1510054
Link To Document