Title of article :
Suppressed ion chromatography for monitoring chemical impurities in steam for geothermal power plants
Author/Authors :
Santoyo، نويسنده , , E and Verma، نويسنده , , S.P and Sandoval، نويسنده , , F and Aparicio، نويسنده , , A and Garc??a، نويسنده , , R، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
9
From page :
281
To page :
289
Abstract :
A suppressed ion chromatography (IC) technique has been evaluated as a chemical monitoring tool for detecting major anions (F−, Cl−, NO3− and SO42−) of condensed steam in geothermal power plants. It is shown that the suppressed IC technique provides a suitable means for preventing possible damage to generating equipment in the geothermal industry. An electrical conductivity detector (0.1 μS sensitivity) with an anion-exchange column (IonPac AS4A-SC), a micro-membrane suppressor (AMMS II), and an isocratic high-pressure pump system were successfully used for detecting low concentrations of inorganic anions. Method detection limits for the anions of interest were <0.184 mg/L. Details of the IC methodology as well as some experimental results obtained during its application for the chemical monitoring of geothermal steam pipes are also described.
Keywords :
Inorganic ions
Journal title :
Journal of Chromatography A
Serial Year :
2002
Journal title :
Journal of Chromatography A
Record number :
1510261
Link To Document :
بازگشت