Title of article :
Application of high-performance liquid chromatography with amperometric and coulometric detection to the analysis of SZ1677, a new neuromuscular blocking agent, and its two derivatives
Author/Authors :
B?a?ewicz، نويسنده , , Agata and Fija?ek، نويسنده , , Zbigniew and Warowna-Grze?kiewicz، نويسنده , , Ma?gorzata and Banasiuk، نويسنده , , Justyna، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
114
To page :
118
Abstract :
A HPLC method with amperometric and coulometric detection for the determination of SZ1677 and its two derivatives SZ1676 and SZ1823 has been developed. This active substance is under development (clinical trial) and there are no analytical methods published for the determination of SZ1677 thus far. The limit of quantitation for SZ1677 was 25 and 100 ng ml−1 by the coulometric and amperometric detection, respectively. The elaborate method for the simultaneous analysis of SZ1677 and its two derivatives proved to be fast, precise, accurate and sensitive.
Keywords :
Electrochemical detection , Coulometric electrode array detection , SZ1677 , Coularray , Muscle relaxant , amperometric detection
Journal title :
Journal of Chromatography A
Serial Year :
2008
Journal title :
Journal of Chromatography A
Record number :
1511172
Link To Document :
بازگشت