Title of article :
Validation of a liquid chromatography–tandem mass spectrometry method to enable quantification of 3-iodothyronamine from serum
Author/Authors :
DeBarber، Peter A. نويسنده , , Andrea E. and Geraci، نويسنده , , Travis and Colasurdo، نويسنده , , Vincent P. and Hackenmueller، نويسنده , , Sarah A. and Scanlan، نويسنده , , Thomas S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
55
To page :
59
Abstract :
There is great interest lately in the availability of analytical methods for quantification of 3-iodothyronamine from blood and tissues. To date, no validated method for determination of 3-iodothyronamine from biological matrices has been described. Detailed in this report is an LC–MS/MS method that permits accurate and reproducible quantification of pharmacological concentrations of 3-iodothyronamine from rat serum, with a 0.0008 M lower limit of quantification. Endogenous 3-iodothyronamine was observed from rodent and human serum (0.2 mL) at the method limit of detection. In summary, the LC–MS/MS method enables quantification of circulating 3-iodothyronamine to allow examination of a relationship with biological activity.
Keywords :
3-Iodothyronamine , LC–MS/MS , serum
Journal title :
Journal of Chromatography A
Serial Year :
2008
Journal title :
Journal of Chromatography A
Record number :
1511345
Link To Document :
بازگشت