• Title of article

    Uncertainty assessment of polychlorinated dibenzo-p-dioxins and dibenzofuran and dioxin-like polychlorinated biphenyl analysis in stationary source sample emissions in accordance with the impending European standard EN-1948 using fly ashes

  • Author/Authors

    Martيnez، نويسنده , , K. and Rivera-Austrui، نويسنده , , J. and Adrados، نويسنده , , M.A. and Abalos، نويسنده , , M. and Llerena، نويسنده , , J.J. and van Bavel، نويسنده , , B. Gato-Rivera، نويسنده , , J. and Abad، نويسنده , , E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    7
  • From page
    5888
  • To page
    5894
  • Abstract
    The analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) present in stack gas emissions and solid residues from incinerators will be mandatory in the foreseeable future. European standard EN-1948 is in the process of being updated through the addition of a new Part 4 related to the analysis of the 12 dl-PCBs. Therefore, either a comprehensive and reliable method capable of analyzing all of these 29 compounds (12 dl-PCBs and 17 2,3,7,8-PCDD/Fs) needs to be developed, or the existing PCDD/F analytical procedure must be adapted to include the dl-PCBs. This study has taken the latter approach of modifying PCDD/F methodology and in particular the fractionation step, by isolating dioxins and dl-PCBs into separate fractions ready for high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS) analysis. Results obtained from the analysis of Certified Reference Materials (CRM-490 and CRM-615) and fly ashes from the European Committee for Standardization (CEN) intercalibration study demonstrated that the proposed methodology is appropriate to determine the dl-PCBs in accordance with the impending European standard EN-1948. Uncertainty values obtained during the validation of the analytical methodology were 13% total I-TEQ (International Toxic Equivalent) for PCDD/Fs and 31% total WHO-TEQ (World Health Organization Toxic Equivalent) in the case of dl-PCBs. In addition, ‘real’ samples such as emissions and fly ashes were successfully analyzed following the proposed analytical method.
  • Keywords
    EN-1948 , Emissions , Fly ash , dl-PCBs , PCDD/Fs , uncertainty
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2009
  • Journal title
    Journal of Chromatography A
  • Record number

    1512242