Title of article :
Enhancing the detection sensitivity of trace analysis of pharmaceutical genotoxic impurities by chemical derivatization and coordination ion spray-mass spectrometry
Author/Authors :
Bai، نويسنده , , Lin and Sun، نويسنده , , Mingjiang and An، نويسنده , , Jianguo and Liu، نويسنده , , David Q. and Chen، نويسنده , , Ted K. and Kord، نويسنده , , Alireza S. Sarvestani، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
302
To page :
306
Abstract :
Many pharmaceutical genotoxic impurities are neutral molecules. Trace level analysis of these neutral analytes is hampered by their poor ionization efficiency in mass spectrometry (MS). Two analytical approaches including chemical derivatization and coordination ion spray-MS were developed to enhance neutral analyte detection sensitivity. The chemical derivatization approach converts analytes into highly ionizable or permanently charged derivatives, which become readily detectable by MS. The coordination ion spray-MS method, on the other hand, improves ionization by forming neutral-ion adducts with metal ions such as Na+, K+, or NH4+ which are introduced into the electrospray ionization source. Both approaches have been proven to be able to enhance the detection sensitivity of neutral pharmaceuticals dramatically. This article demonstrates the successful applications of the two approaches in the analysis of four pharmaceutical genotoxic impurities identified in a single drug development program, of which two are non-volatile alkyl chlorides and the other two are epoxides.
Keywords :
Coordination ion spray-MS , Chemical derivatization , Genotoxic impurity , trace analysis
Journal title :
Journal of Chromatography A
Serial Year :
2010
Journal title :
Journal of Chromatography A
Record number :
1512701
Link To Document :
بازگشت