Title of article :
A high performance liquid chromatography-electrochemical array method for the measurement of oxidative/nitrative changes in human urine
Author/Authors :
S. Saravanabhavan، نويسنده , , Gurusankar and Blais، نويسنده , , Erica and Vincent، نويسنده , , Renaud and Kumarathasan، نويسنده , , Prem، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
Oxidative stress has been implicated in various pathologies as well as in environmental pollutant-induced negative health outcomes. In this work we have developed an analytical method to measure oxidative stress markers namely m-, o-tyrosine, 3-chlorotyrosine, 3-nitrotyrosine, and the DNA damage marker 8-hydroxy deoxyguanosine in human urine. The method involves the base hydrolysis of the urine sample followed by solid phase extraction of target analytes using a reverse phase polymeric sorbent column prior to the HPLC-EC analysis. The recovery studies indicated that the overall method recovery for all analytes were >60%. The limit of quantification of all target analytes was <10 nM with a linear range from 2 nM to 150 μM. The applicability of this method is demonstrated by analyzing the above markers in healthy human urine (n = 10) samples.
Keywords :
8-OH-dG , HPLC-EC array , oxidative stress , biomarkers , tyrosine , Urine Analysis