    High-temperature solvent stability of sol–gel germania triblock polymer coatings in capillary microextraction on-line coupled to high-performance liquid chromatography

  • Author/Authors

    Segro، نويسنده , , Scott S. and Malik، نويسنده , , Abdul، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    7
  • From page
    5746
  • To page
    5752
  • Abstract
    Germania-based sol–gel organic–inorganic hybrid coatings were prepared for on-line coupling of capillary microextraction with high-performance liquid chromatography. For this, a germania-based sol–gel precursor, tetra-n-butoxygermane and a hydroxy-terminated triblock copolymer, poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) were used. These sol–gel germania triblock polymer coatings were chemically anchored to the inner walls of a fused silica capillary (0.25 mm I.D.) in course of its evolution from the sol solution. Scanning electron microscopy images of the sol–gel germania triblock polymer coating were obtained to estimate the coating thickness. For the first time, the analyte distribution constants between a sol–gel germania organic–inorganic hybrid coating and the samples (Kcs) were determined. For a variety of analytes from different chemical classes, including polycyclic aromatic hydrocarbons (PAHs), ketones, alcohols, phenols and amines, the Kcs values ranged from 8.1 × 101 to 5.6 × 104. Also, for the first time, the stability of the sol–gel germania-based coating in high-temperature reversed-phase solvent environment was evaluated. The sol–gel germania triblock polymer coatings were capable of surviving exposure to high-temperature solvent conditions (200 °C) with little change in extraction capabilities. This demonstrates that sol–gel germania triblock polymer hybrid materials might be suitable for further applications in high-temperature HPLC. The reproducibility of the method for preparation of the sol–gel germania triblock polymer coatings was also evaluated, and the capillary-to-capillary RSD values ranged from 5.3 to 6.5%. The use of higher flow rates in extraction was found to significantly reduce the time required (from 30–40 to 10–15 min) to reach equilibrium between the sol–gel germania triblock polymer coating and the analytes in the sample solution.
  • Keywords
    Sample preconcentration , Triblock polymer , Sol–gel germania , Capillary microextraction (CME) , Poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) , High-temperature , High-Performance Liquid Chromatography (HPLC) , On-line coupling , CME–HPLC
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2010
  • Journal title
    Journal of Chromatography A
  • Record number

    1513349