Title of article :
Rapid and sensitive drug metabolism studies by SU-8 microchip capillary electrophoresis-electrospray ionization mass spectrometry
Author/Authors :
Nordman، نويسنده , , Nina and Sikanen، نويسنده , , Tiina and Moilanen، نويسنده , , Maria-Elisa and Aura، نويسنده , , Susanna and Kotiaho، نويسنده , , Tapio and Franssila، نويسنده , , Sami and Kostiainen، نويسنده , , Risto، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
739
To page :
745
Abstract :
Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface, and an electrospray ionization (ESI) emitter were developed to improve the speed and throughput of metabolism research. Validation of the microchip method was performed using bufuralol 1-hydroxylation via CYP450 enzymes as the model reaction. The metabolite, 1-hydroxybufuralol, was easily separated from the substrate (Rs = 0.5) with very good detection sensitivity (LOD = 9.3 nM), linearity (range: 50–500 nM, r2 = 0.9997), and repeatability (RSDArea = 10.3%, RSDMigration time = 2.5% at 80 nM concentration without internal standard). The kinetic parameters of bufuralol 1-hydroxylation determined by the microchip capillary electrophoresis (CE)-ESI/mass spectrometry (MS) method, were comparable to the values presented in literature as well as to the values determined by in-house liquid chromatography (LC)-UV. In addition to enzyme kinetics, metabolic profiling was demonstrated using authentic urine samples from healthy volunteers after intake of either tramadol or paracetamol. As a result, six metabolites of tramadol and four metabolites of paracetamol, including both phase I oxidation products and phase II conjugation products, were detected and separated from each other within 30–35 s. Before analysis, the urine samples were pre-treated with on-chip, on-line liquid-phase microextraction (LPME) and the results were compared to those obtained from urine samples pre-treated with conventional C18 solid-phase extraction (SPE, off-chip cartridges). On the basis of our results, the SU-8 CE-ESI/MS microchips incorporating on-chip sample pre-treatment, injection, separation, and ESI/MS detection were proven as efficient and versatile tools for drug metabolism research.
Keywords :
Epoxy photoresist SU-8 , mass spectrometry , Metabolism , Microfluidics , electrophoresis
Journal title :
Journal of Chromatography A
Serial Year :
2011
Journal title :
Journal of Chromatography A
Record number :
1513759
Link To Document :
بازگشت