Title of article :
A cost-effective method for estimating di(2-ethylhexyl)phthalate in coastal sediments
Author/Authors :
Muٌoz-Ortuٌo، نويسنده , , M. and Argente-Garcيa، نويسنده , , A. and Moliner-Martيnez، نويسنده , , Y. and Verdْ-Andrés، نويسنده , , J. and Herrلez-Hernلndez، نويسنده , , R. and Picher، نويسنده , , M.T. and Campيns-Falcَ، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
This study describes the development of a new method for the analysis of di(2-ethylhexyl)phthalate (DEHP) using 0.1–0.3 g of sediment sample, based on matrix solid phase dispersion (MSPD) using C18 as dispersant phase (0.4 g) and acetonitrile–water as eluting solvent (3.4 mL 1:3.25, v/v). No evaporation step is required. 3 mL of extracts were processed on-line by in-tube solid phase microextraction (IT-SPME) coupled to capillary liquid chromatography (CapLC) and diode array detector (DAD). A short analytical column Zorbax SB C18 (35 × 0.5 mm, 5 μm) provided suitable results. FTIR-ATR was employed for characterizing sediment samples and MSPD procedure. The total analysis time was less than 20 min (MSPD takes about 10 min). The utility of the described approach has been tested by analyzing several real samples. No matrix effect was found. Achieved precision was less than 10% for DEHP estimation. Detection limits in samples were 270 and 90 μg/kg for 0.1 and 0.3 g of taken sediment, respectively.
Keywords :
sediment , Short capillary particulate column , Di(2-ethylhexyl)phthalate , Matrix solid phase dispersion
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A