Title of article :
Ultrahigh performance liquid chromatographic analysis and magnetic preconcentration of polycyclic aromatic hydrocarbons by Fe3O4-doped polymeric nanoparticles
Author/Authors :
Zhang، نويسنده , , Xicui and Xie، نويسنده , , Shunping and Paau، نويسنده , , Man Chin and Zheng، نويسنده , , Baozhan and Yuan، نويسنده , , Hongyan and Xiao، نويسنده , , Dan and Choi، نويسنده , , Martin M.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
9
From page :
1
To page :
9
Abstract :
This paper reports the synthesis of hydrophilic–hydrophobic magnetic Fe3O4-doped polymeric nanoparticles (MPNP) and its application for preconcentration of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples for ultrahigh performance liquid chromatographic (UHPLC) analysis. The MPNP were prepared from highly charged poly(styrene-divinylbenzene-co-4-vinylbenzenesulfonic acid sodium salt) nanoparticles impregnated with Fe2+ via the electrostatic attraction and by microwave heating. The MPNP are relatively uniform in size with an average diameter of 50 nm and have a magnetic saturation value of 24.5 emu/g. The hydrophilic–hydrophobic MPNP could easily disperse in water. The phenyl moieties of MPNP assist the adsorption of PAHs via both hydrophobic and π–π interactions. The separation of the PAHs-adsorbed MPNP from water could be easily achieved by a permanent magnet and the adsorbed PAHs were back extracted into acetonitrile for UHPLC analysis. The UHPLC separation of PAHs is very quick and could be achieved within 1.6 min. Factors affecting the extraction and desorption were investigated in detail. Under the optimum experimental conditions, the recoveries of various PAHs including acenaphthylene, anthracene, fluoranthene, fluorene, phenanthrene, and pyrene in water samples at three different concentrations are 75.7–102.9, 77.8–101.2, 86.3–100.7, 88.5–99.7, 92.0–106.4, and 81.6–98.5%, respectively. The recovery SDs are 0.30–8.20% and the instrumental limits of detection are 10.83–18.53 nM. The proposed technique combining hydrophobic extraction and magnetic separation coupled with UHPLC could provide a fast, convenient and sensitive method for the determination of PAHs in water samples.
Keywords :
Hydrophilic–hydrophobic magnetic polymeric nanoparticles , Solid-phase extraction , Polycyclic aromatic hydrocarbons , Ultrahigh performance liquid chromatography
Journal title :
Journal of Chromatography A
Serial Year :
2012
Journal title :
Journal of Chromatography A
Record number :
1515723
Link To Document :
بازگشت