Title of article :
Peak capacity optimisation for high resolution peptide profiling in complex mixtures by liquid chromatography coupled to time-of-flight mass spectrometry: Application to the Conus consors cone snail venom
Author/Authors :
Eugster، نويسنده , , Philippe J. and Biass، نويسنده , , Daniel and Guillarme، نويسنده , , Davy and Favreau، نويسنده , , Philippe and Stِcklin، نويسنده , , Reto and Wolfender، نويسنده , , Jean-Luc، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
13
From page :
187
To page :
199
Abstract :
The high resolution profiling of complex mixtures is indispensable for obtaining online structural information on the highest possible number of the analytes present. This is particularly relevant for natural extracts, as for the venom of the predatory marine snail Conus consors, which contains numerous bioactive peptides with molecular masses ranging between 1000 and 5000 Da. The goal of the present work was to maximise peak capacity of peptides separations by LC–MS while maintaining a reasonable analysis time. The best gradient performance using the C. consors venom as a real sample was obtained with a mobile phase flow rate as high as possible to maximise performance in the gradient mode, and gradient time comprised between 75 and 350 min when using a 150 mm column length. The present study also confirmed that an elevated temperature (up to 90 °C) improves performance under ultra-high pressure liquid chromatography (UHPLC) conditions. However, the thermal stability of the analytes had to be critically evaluated. For the profiling of C. consors, analyte degradation was not clearly observable at 90 °C with analysis times of approximately 100 min. Finally, the MS source was found to cause significant additional band broadening in the UHPLC mode ( σ e x t 2 was 10–24 times higher using TOF-MS vs. UV detection). Thus, if the MS contributes strongly to the peak capacity loss, classical 2.1 mm I.D. columns can be replaced by 3.0 mm I.D. to mitigate this problem. Based on these considerations, the optimal generic profiling conditions applied to the C. consors venom provided a peak capacity higher than 1100 for a gradient time of around 100 min, doubling the values reached by classical HPLC separation. UHPLC-QTOF-MS/MS experiments carried out in these conditions provided exploitable data that matched with peptides present in the C. consors venom. These optimal LC conditions are thus compatible with online peptide deconvolution and matching against transcriptomic data and, to some extent, de novo sequencing in such complex mixtures.
Keywords :
UHPLC-TOF-MS , profiling , Peak capacity , high resolution , Venom peptides , Conus consors
Journal title :
Journal of Chromatography A
Serial Year :
2012
Journal title :
Journal of Chromatography A
Record number :
1516636
Link To Document :
بازگشت