Title of article :
Screening approach, optimisation and scale-up for chiral liquid chromatography of cathinones
Author/Authors :
Perera، نويسنده , , R. Wimal H. and Abraham، نويسنده , , Ijeoma and Gupta، نويسنده , , Shradha and Kowalska، نويسنده , , Patrycja and Lightsey، نويسنده , , Danielle and Marathaki، نويسنده , , Chrysoula and Singh، نويسنده , , Nagendra S. and Lough، نويسنده , , W. John، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
9
From page :
189
To page :
197
Abstract :
Screening approaches adopted in pharmaceutical companies for chiral LC method development may be quite complicated and sophisticated in order to guarantee a high success rate. However in other environments it may be of more value to assess how simple a screen might be used to still have a good chance of achieving success. The genuine need to develop chiral separations for the former ‘legal-high’ drug mephedrone and related cathinones of topical interest presented a good opportunity to develop this theme. In initial work on mephedrone itself, no chiral separation was observed on Chirobiotic V, Cyclobond I 2000 DNP, Whelk-O1 and AmyCoat using reversed phase mobile phases. However, using normal phase solvents, chiral separation was observed on all the chiral stationary phases (CSP) used except Chiralcel OJ-H. Of the chiral separations observed on RegisPack, RegisCell and Whelk-O1, some optimisation work was carried out on the latter two which had showed the greatest enantioselectivity. Following optimisation, the best enantioselectivity (1.59) and enantioresolution (5.90) was found with a 250 mm × 4.6 mm I.D. Whelk-O1 column using a propan-2-ol (IPA)–hexane–trifluoroacetic acid (TFA)–triethylamine (TEA) (10:90:0.05:0.05, v/v/v/v) mobile phase. Subsequent screening on other cathinones was restricted to RegisPack, RegisCell and Whelk-O1 or equivalent phases with two mobile phases and this gave a very good success rate. Indeed it was possible to separate all six cathinones on one column, RegisCell, with one mobile phase, propan-2-ol–hexane–TFA (15:85:0.1, v/v/v) but obviously it had been necessary to go through the 3-column screen to arrive at this finding. While Whelk-O1 was not so successful, ease of optimisation on this phase was again a feature. To illustrate the applicability of these separations, it was shown that, as a basis for semi-preparative work, the optimsed mephedrone separation on Whelk-O1 could be scaled-up to a 2000 μl injection of a 1.0 mg ml−1 solution in mobile phase (2.0 mg on-column) while still using the 250 mm × 4.6 mm I.D. analytical column.
Keywords :
Chiral LC screening , Cathinones , RegisCell , Scale-up , Optimisation , Whelk-O1
Journal title :
Journal of Chromatography A
Serial Year :
2012
Journal title :
Journal of Chromatography A
Record number :
1517159
Link To Document :
بازگشت