• Title of article

    Comparison of two ionic liquid dispersive liquid–liquid microextraction approaches for the determination of benzoylurea insecticides in wastewater using liquid chromatography–quadrupole-linear ion trap–mass spectrometry: Evaluation of green parameters

  • Author/Authors

    Vلzquez، نويسنده , , M.M. Parrilla and Vلzquez، نويسنده , , P. Parrilla and Galera، نويسنده , , M. Martيnez and Moreno، نويسنده , , A. Uclés، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    9
  • From page
    1
  • To page
    9
  • Abstract
    Two dispersive liquid–liquid microextraction (DLLME) approaches including temperature-controlled ionic liquid dispersive liquid–liquid microextraction (TCIL-DLLME) and ultrasound-assisted ionic liquid dispersive liquid–liquid microextraction (US-IL-DLLME) were compared for the extraction of six benzoylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, lufenuron and flufenoxuron) from wastewater samples prior to their determination by high-performance liquid chromatography with a hybrid triple quadrupole-linear ion trap–mass spectrometer (LC–QqLIT–MS/MS). Influential parameters affecting extraction efficiency were systematically studied and optimized and the most significant green parameters were quantified and compared. The best results were obtained using the US-IL-DLLME procedure, which employed the IL 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) and methanol (MeOH) as extraction and disperser solvent, respectively. US-IL-DLLME procedure was fast, easy, low environmental toxicity and, it was also able to successfully extract all selected benzoylureas. This method was extensively validated with satisfactory results: limits of detection and quantification were in the range 0.5–1.0 ng L−1 and 1.5–3.5 ng L−1, respectively, whereas recovery rates ranged from 89 to 103% and the relative standard deviations were lower than 13.4%. The applicability of the method was assessed with the analysis of effluent wastewater samples from a wastewater treatment plant located in an agricultural zone of Almería (Spain) and the results indicated the presence of teflubenzuron at mean concentration levels of 11.3 ng L−1. US-IL-DLLME sample treatment in combination with LC–QqLIT–MS/MS has demonstrated to be a sensitive, selective and efficient method to determine benzoylurea insecticides in wastewaters at ultra-trace levels.
  • Keywords
    Dispersive liquid–liquid microextraction , Ionic liquid , Wastewater , Liquid chromatography–quadrupole-linear ion trap , Tandem mass spectrometry , Insecticides
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2014
  • Journal title
    Journal of Chromatography A
  • Record number

    1517229