Title of article :
Untargeted and targeted comprehensive two-dimensional GC analysis using a novel unified high-speed triple quadrupole mass spectrometer
Author/Authors :
Tranchida، نويسنده , , Peter Quinto and Franchina، نويسنده , , Flavio Antonio and Zoccali، نويسنده , , Mariosimone and Pantٍ، نويسنده , , Sebastiano and Sciarrone، نويسنده , , Danilo and Dugo، نويسنده , , Paola and Mondello، نويسنده , , Luigi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
153
To page :
159
Abstract :
The present manuscript is focused on the evaluation of a novel high-speed triple quadrupole mass spectrometer (QqQ MS), carried out under extreme GC conditions, namely those generated by a flow-modulated (FM) comprehensive two-dimensional GC (GC × GC) system. The novel QqQ MS system is capable of operation under high speed conditions, in both full-scan (maximum scan speed: 20,000 amu/s) and multiple reaction monitoring (MRM) modes. Moreover, the QqQ MS instrument can generate simultaneous full scan/MRM data, also in a very rapid manner. An FM GC × GC–MSMS method was developed for the simultaneous full-scan qualitative analysis of untargeted essential oil compounds, and MRM quali/quantitative analysis of targeted ones, namely three preservatives [o-phenylphenol (OPP), butylated hydroxytoluene (BHT), butylated hydroxyanisole (BHA)]. The QqQMS system generated a sufficient number of data points per peak, for both qualitative and quantitative purposes. The degree of sensitivity, reached through the MRM analysis, widely exceeded current-day regulations. Method validation, related to the MRM analysis, was performed considering retention time, peak area and ion ratio repeatability, limits of detection and quantification, and accuracy. Additionally, a spearmint essential oil was spiked with 5 phytosanitary compounds at the 1 ppb level, and analysed through an MRM-only GC × GC–MSMS application. Emphasis was devoted not only on sensitivity (satisfactory for all the contaminants), but also on the importance of precursor ion selection, and of the GC × GC separation process. Finally, sensitivity was compared between the MRM and SIM modes, in scan/MRM, MRM, scan/SIM and SIM analyses, performed on a mixture of 22 phytosanitary products, at a concentration level in the 50–150 ppb range.
Keywords :
Comprehensive two-dimensional gas chromatography , Food analysis , Pesticide analysis , Essential oil , Flow modulation , Triple quadrupole mass spectrometry
Journal title :
Journal of Chromatography A
Serial Year :
2013
Journal title :
Journal of Chromatography A
Record number :
1517788
Link To Document :
بازگشت