• Title of article

    Resolution of a racemic pharmaceutical intermediate: A comparison of preparative HPLC, steady state recycling, and simulated moving bed

  • Author/Authors

    Grill، نويسنده , , Charles M and Miller، نويسنده , , Larry and Yan، نويسنده , , Tony Q، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    8
  • From page
    101
  • To page
    108
  • Abstract
    Preparative HPLC and simulated moving bed (SMB) chromatography were used to resolve significant quantities of a racemic pharmaceutical intermediate. In addition, smaller scale studies using closed-loop recycling and steady state recycling (SSR) were performed so that a meaningful comparison of all these techniques could be made using the same real world separation. A highly optimized, six-column SMB process was clearly the superior technique and was used for the process-scale (247 kg of racemate) resolution. At the more moderate lab-scale (33 kg of racemate and 19 kg of racemate), a frequently used but less optimized eight-column SMB process was used. It was found that SSR was comparable to the lab-scale SMB process in productivity and solvent consumption. Thus, it appears that SSR can be a useful choice at such moderate scales. Finally, at moderate scales when neither SSR nor SMB is available, it was found that acceptable results were obtained with both closed-loop recycling and with a two-step preparative process.
  • Keywords
    Steady state recycling , Simulated moving bed , Preparative chromatography , Enantiomer separation
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2004
  • Journal title
    Journal of Chromatography A
  • Record number

    1519715