Title of article
Suppressor current switching: a simple and effective means to reduce background noise in ion chromatography
Author/Authors
Rantakokko، نويسنده , , Panu and Mustonen، نويسنده , , Satu and Vartiainen، نويسنده , , Terttu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
8
From page
265
To page
272
Abstract
Background noise in ion chromatography with suppressed conductivity detection was significantly reduced for the period of time when the electric current to an anion self regenerating suppressor (ASRS) running in the recycle mode was turned-off. With high capacity AS11-HC columns, it was possible to maintain current free conditions from the beginning of the run past the chloride peak, which enables routine high sensitivity analysis of early to mid eluting peaks. This suppressor current switching was utilized for the analysis of bromate in drinking water with large volume injection using on-line removal of chloride by an On-Guard Ag+-cartridge. The method detection limit (MDL) was 0.21 μg/l in fortified reagent water. Coelution of bromate with an unknown compound was observed, but it was solved by the optimization of gradient program.
Keywords
Suppressor current switching , Water analysis , Bromate , background noise
Journal title
Journal of Chromatography A
Serial Year
2003
Journal title
Journal of Chromatography A
Record number
1519895
Link To Document