• Title of article

    Enantiomeric analysis of polycyclic musks in water by chiral gas chromatography–tandem mass spectrometry

  • Author/Authors

    Wang، نويسنده , , Lili and McDonald، نويسنده , , James A. and Khan، نويسنده , , Stuart J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    10
  • From page
    66
  • To page
    75
  • Abstract
    Galaxolide (HHCB), tonalide (AHTN), phantolide (AHDI), traseolide (ATII) and cashmeran (DPMI) are synthetic polycyclic musks (PCMs). They are all commonly used in fragrance industries as racemic mixtures. A sensitive and robust enantioselective analytical method was developed to facilitate measurement of these chemicals in wastewater and environmental samples. The method is based on gas chromatography with tandem mass spectrometry (GC–MS/MS). Enantioseparation was assessed using four commercially available chiral capillary columns. Optimised resolution was achieved using a dual-column configuration of a chiral heptakis(2,3- di-O-methyl-6-O-t-butyl dimethylsilyl)-β-cyclodextrin column combined with a (non-chiral) HP-5MS column. This configuration was demonstrated to be capable of effectively resolving all commercially manufactured enantiomers of these five PCMs. Method detection limits for single enantiomers in drinking water and surface water range between 1.01 and 2.39 ng L−1. Full validation of the application of this method in these aqueous matrices is provided.
  • Keywords
    Enantiomers , Polycyclic musks , Enantiomeric analysis , Gas chromatography , mass spectrometry
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2013
  • Journal title
    Journal of Chromatography A
  • Record number