Title of article :
Preparative separation of gambogic acid and its C-2 epimer using recycling high-speed counter-current chromatography
Author/Authors :
Han، نويسنده , , Quan-Bin and Song، نويسنده , , Jing-Zheng and Qiao، نويسنده , , Chun Feng and Wong، نويسنده , , Lina and Xu، نويسنده , , Hong Xi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
4
From page :
298
To page :
301
Abstract :
A recycling counter-current chromatographic system was first set up with a high-speed counter-current chromatography instrument coupled with a column switching valve. This system was first successfully applied to the preparative separation of epimers, gambogic acid and epigambogic acid from Garcinia hanburyi using n-hexane–methanol–water (5:4:1, v/v/v) as the two-phase solvent system. As a result, 28.2 mg gambogic acid and 18.4 mg epigambogic acid were separated from 50 mg of mixture. Their purities were both above 97% as determined by HPLC. The chemical structures were then identified by their 1H NMR and 13C NMR spectra.
Keywords :
Recycling counter-current chromatography , Preparative separation , Epimer , Garcinia hanburyi , Gambogic acid , Epigambogic acid
Journal title :
Journal of Chromatography A
Serial Year :
2006
Journal title :
Journal of Chromatography A
Record number :
1521693
Link To Document :
بازگشت