Title of article
Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers: Application to the passive sampling of the polar herbicides in aquatic environments
Author/Authors
Mazzella، نويسنده , , Nicolas and Dubernet، نويسنده , , Jean-François and Delmas، نويسنده , , François، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
10
From page
42
To page
51
Abstract
This work set out the laboratory calibration of the passive samplers such as polar organic chemical integrative samplers (POCISs) which preconcentrate hydrophilic organic contaminants in aqueous medium. We compared the two different configurations available (i.e. pesticide and pharmaceutical POCISs) for sampling different classes of herbicides representative of a wide range of polarity (5.34 ≥ log Kow ≥ −1.70). The results showed that pharmaceutical configuration was probably more convenient for sampling basic, neutral or acidic herbicides. Afterward, we performed a kinetic study with the pharmaceutical POCIS only. This calibration revealed linear and integrative uptakes of several herbicides for 21 days. For some compounds like sulcotrione, mesotrione, deisopropylatrazine (DIA) and deethylatrazine (DEA), the linear uptake model was only valid for 10 days. Lastly, we observed an increase of the sampling rates with the hydrophobicity of the herbicides.
Keywords
HPLC-UV/Vis , Phenylureas , triazines , Passive samplers , Triketones , Freshwater quality