Title of article :
Content uniformity and assay requirements in current regulations
Author/Authors :
Bلnfai، نويسنده , , Balلzs and Ganzler، نويسنده , , Katalin and Kemény، نويسنده , , Sلndor، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
7
From page :
206
To page :
212
Abstract :
The acceptance of a tablet batch is based both on the content uniformity test and on the assay. It is shown that these two characteristics are not independent, and the acceptance criteria for them are not even consistent. For content uniformity range three methods of calculation are compared: the present European Pharmacopoeia method, a tolerance range method with improved k tolerance factor and a one-way random effects analysis of variance model. To resolve the inconsistency several options are discussed: applying the holistic content uniformity range alone; using content uniformity standard deviation and assay mean simultaneously or applying a criterion based on Taguchiʹs quadratic loss function.
Keywords :
Random effects ANOVA , content uniformity , assay , Acceptance criteria , Tolerance range , Pharmacopoeia , Taguchiיs quadratic loss function
Journal title :
Journal of Chromatography A
Serial Year :
2007
Journal title :
Journal of Chromatography A
Record number :
1521981
Link To Document :
بازگشت