Title of article :
Large volume injection in ion chromatography: Separation of rubidium and strontium for on-line inductively coupled plasma mass spectrometry determination of strontium isotope ratios
Author/Authors :
Garcيa-Ruiz، نويسنده , , Silvia and Moldovan، نويسنده , , Mariella and Garcيa Alonso، نويسنده , , J. Ignacio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
8
From page :
274
To page :
281
Abstract :
Large volume injection, up to 5 mL, was evaluated and optimised for the on-line ion chromatographic separation of Rb and Sr before ICP-MS measurement of Sr isotope ratios. Flat-topped chromatographic peaks, ideally suited for multicollector ICP-MS isotope ratio measurements, could be obtained when the composition of the mobile phase (nitric acid and 18-crown-6 ether) was identical to the matrix of the sample. Under those conditions rubidium eluted at the dead volume of the column while strontium produced a flat-topped transient signal with several minutes of stable plateau. On-line data acquisition during several minutes at the plateau of Sr signal allowed high precision Sr isotope ratio measurement. The developed procedure was evaluated for Sr isotope ratio measurements on different types of samples, including cider, apples, apple leaves, and soil extracts, in the frame of a long-term project aiming at origin authentication using strontium isotope ratio measurements. It was observed that sample matrix caused broadening of the strontium chromatographic peak and loss of flat-topped peak profile. Under those circumstances the addition of the complexing crown-ether 18-crown-6 both to samples and chromatographic eluent provided two distinct advantages. First, a drastic increase in the retention of strontium was observed which could be modulated by increasing the concentration of nitric acid in the eluent up to 900 mM. This increase in the eluent HNO3 concentration allowed the application of the method to acid soil digests and other high acidity samples. Second, the matrix of the sample did not affect any more the chromatographic peak profile and similar chromatographic separations could be obtained for samples and standards maintaining the flat-topped Sr peak profile. Sample preparation consisted of a simple 1:10 dilution of the cider or pre-treated solid samples by adding HNO3 (900 mM) and 18-crown-6 ether (5 mM) to obtain similar composition in the sample solution and the HPLC eluent.
Keywords :
Flat-topped peak profile , Ion chromatography , Large volume injection , Strontium isotope ratios , MC-ICP-MS
Journal title :
Journal of Chromatography A
Serial Year :
2007
Journal title :
Journal of Chromatography A
Record number :
1523246