Title of article :
Determination of microcystins in biological samples by matrix solid-phase dispersion and liquid chromatography–mass spectrometry
Author/Authors :
Ruiz، نويسنده , , Marيa José and Cameلn، نويسنده , , Ana Marيa and Moreno، نويسنده , , Isabel Marيa and Picَ، نويسنده , , Yolanda، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
A method for the detection and quantification of the microcystins (MCs)—MC-LR, MC-RR and MC-YR—in biological samples by matrix solid-phase dispersion (MSPD) has been developed. The optimum extraction conditions were 500 mg of liver or kidney, C18 bonded silica as dispersant, and a mixture methanol–water (70:30) as eluent. The MCs were determined by liquid chromatography electrospray mass spectrometry (LC/ES/MS). Recoveries of biological extracts at three different spiked levels (1–10 mg kg−1) ranged from 40.5 to 87.0% in liver, and from 52.5 to 74.5 in kidney. R.S.D.s were <15.6% and <10.6%, respectively. The detection and quantification limits were 0.05 and 0.5 mg kg−1, for all MCs. The method was applied to MCs detection in liver and kidney of rat previously injected i.p. with MC-LR. Results showed the presence of MC-LR in the liver of the animals injected with the highest dose.
Keywords :
Microcystins , Matrix solid-phase dispersion , Liver , Kidney , Rat , Liquid chromatography–mass spectrometry
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A