Title of article :
Determination of total sulfite in wine: Zone electrophoresis–isotachophoresis quantitation of sulfate on a chip after an in-sample oxidation of total sulfite
Author/Authors :
Masar Gashi، نويسنده , , Mari?n and Dankov?، نويسنده , , Mariana and ?lveck?، نويسنده , , Eva and Stachurov?، نويسنده , , Adela and Kaniansky، نويسنده , , Du?an and Stanislawski، نويسنده , , Bernd، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
7
From page :
101
To page :
107
Abstract :
This work deals with the determination of total sulfite in wine. The determination combines an in-sample hydrogen peroxide oxidation of total sulfite in alkalized wine to sulfate with the separation and quantitation of the latter anion by zone electrophoresis (ZE) on-line coupled with isotachophoresis (ITP) on a column-coupling chip. Sample clean up, integrated into the ITP–ZE separation, eliminated wine matrix in an extent comparable to that provided by a highly selective distillation isolation of sulfite. At the same time, conductivity detection, employed to the detection of sulfate in the ZE stage of the ITP–ZE combination, provided for sulfate the concentration limit of detection corresponding to a 90 μg/l concentration of sulfite in the loaded sample (0.9 μl). Such a detectability allowed a reproducible quantitation of total sulfite when its concentration in wine was 15 mg/l. Formaldehyde binding of free sulfite in wine, included into the pre-column sample preparation, prevented an uncontrolled oxidation of this sulfite form. This step contributed to an unbiased determination of sulfate present in the original wine sample (this determination corrected for the concentration of sulfate determined in the sample after the peroxide oxidation of sulfite to the value equivalent to the total sulfite). The 99–101% recoveries of sulfite, determined for appropriately spiked wine samples, indicate a very good accuracy of the present method. Such a statement also supports excellent agreements of the results of quantitation based on the in-sample peroxide oxidation of the total sulfite (bound sulfite released at a high pH) with those in which this analyte was isolated from wine by distillation (bound sulfite released at a very low pH).
Keywords :
Electrophoresis on chip , Zone electrophoresis–isotachophoresis chip , Food analysis , Sulfite in food , Wine analysis
Journal title :
Journal of Chromatography A
Serial Year :
2005
Journal title :
Journal of Chromatography A
Record number :
1524219
Link To Document :
بازگشت