Title of article :
Pesticide trace analysis using solid-phase extraction and gas chromatography with electron-capture and tandem mass spectrometric detection in water samples
Author/Authors :
Mart??nez Vidal، نويسنده , , J.L and Pablos Espada، نويسنده , , M.C and Garrido Frenich، نويسنده , , A and Arrebola، نويسنده , , F.J، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
11
From page :
235
To page :
245
Abstract :
Gas chromatography (GC) with electron-capture detection (ECD), mass spectrometry (MS) and tandem mass spectrometry (MS–MS) were employed for the identification of 12 pesticides in water samples. For this purpose, a solid-phase extraction procedure with C18 cartridges was used, optimising the breakthrough volume and the saturation concentration. In GC–MS–MS, the lowest detectable concentrations for the pesticides were between 2 and 26 ng l−1, recoveries ranged from 70 to 133% in water samples spiked at 100 ng l−1 and the relative standard deviations were in the range 5.3 to 17.4%. The proposed analytical methodology was applied to analyse pesticides in wetland samples from Almerı́a (Spain).
Keywords :
pesticides
Journal title :
Journal of Chromatography A
Serial Year :
2000
Journal title :
Journal of Chromatography A
Record number :
1526577
Link To Document :
بازگشت