Title of article :
Determination by high-performance liquid chromatography of ketoprofen in vitro in rat skin permeation samples
Author/Authors :
de Jalَn، نويسنده , , E.Gھ and Josa، نويسنده , , M and Campanero، نويسنده , , M.A and Santoyo، نويسنده , , Susana and Ygartua، نويسنده , , P، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
143
To page :
149
Abstract :
A direct, simple and rapid high-performance liquid chromatographic method has been developed for the determination of ketoprofen with ibuprofen as internal standard. Samples were chromatographed on a 5 μm Kromasil 100 C18 column. The mobile phase was a mixture of acetonitrile–0.01 M KH2PO4 adjusted to pH 1.5 with orthophosphoric acid 85% (60:40, v/v). Detection was at 260 nm and the run time was 10 min. The detector response was found to be linear in the concentration range 0.02 to 40 μg/ml. This HPLC assay has been applied to measure the “in vitro” percutaneous penetration of ketoprofen through rat skin.
Keywords :
Ketoprofen , IBUPROFEN , Nonsteroidal anti-inflammatory drugs
Journal title :
Journal of Chromatography A
Serial Year :
2000
Journal title :
Journal of Chromatography A
Record number :
1526801
Link To Document :
بازگشت