Title of article
Model for temperature estimation of dc-contactors with double-break main contacts
Author/Authors
Paisios، نويسنده , , M.P. and Karagiannopoulos، نويسنده , , C.G. and Bourkas، نويسنده , , P.D.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
10
From page
503
To page
512
Abstract
The double-break arrangement of dc-contactors is advantageous for electrical arc quenching, so the most important disadvantage of the double-break, the higher temperature rise during current carrying operation, is acceptable. However, overheating can be a serious problem. In this paper, a mathematical model is proposed for the steady-state temperature difference distribution of double-break dc-contactors and an experimental verification of the theoretical results attempted. The influence of different dc-contactors’ parameters on the temperature distribution is investigated, and it is convincingly shown that the heat generated is dissipated mainly by the conductors, and that this dominates the optimisation of the dc-contactor temperature rise.
Keywords
Stationary dc-contactor , Double-break main contacts , temperature rise
Journal title
Simulation Modelling Practice and Theory
Serial Year
2007
Journal title
Simulation Modelling Practice and Theory
Record number
1580735
Link To Document