    Model for temperature estimation of dc-contactors with double-break main contacts

  • Author/Authors

    Paisios، نويسنده , , M.P. and Karagiannopoulos، نويسنده , , C.G. and Bourkas، نويسنده , , P.D.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    10
  • From page
    503
  • To page
    512
  • Abstract
    The double-break arrangement of dc-contactors is advantageous for electrical arc quenching, so the most important disadvantage of the double-break, the higher temperature rise during current carrying operation, is acceptable. However, overheating can be a serious problem. In this paper, a mathematical model is proposed for the steady-state temperature difference distribution of double-break dc-contactors and an experimental verification of the theoretical results attempted. The influence of different dc-contactors’ parameters on the temperature distribution is investigated, and it is convincingly shown that the heat generated is dissipated mainly by the conductors, and that this dominates the optimisation of the dc-contactor temperature rise.
  • Keywords
    Stationary dc-contactor , Double-break main contacts , temperature rise