Title of article :
Effect of SAMG entry condition on operator action time for severe accident mitigation
Author/Authors :
Park، نويسنده , , Rae-Joon and Hong، نويسنده , , Seong-Wan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
The effect of SAMG (Severe Accident Management Guidance) entry condition on operator action time for prevention of reactor vessel failure in the OPR1000 (Optimized Power Reactor 1000) was evaluated with a comparison to other conditions using the SCDAP/RELAP5/MOD3 computer code in detail. Dominant severe accident sequences, such as a station blackout, a total loss of feedwater, a small and medium break loss of coolant accidents without a safety injection were evaluated in this study. The results showed that a core exit temperature of 480 °C for the SAMG entry condition was too early, but a core exit temperature of 1000 °C was too late for operator action time to prevent reactor vessel failure. The SAMG entry condition of a core exit temperature of 650 °C for the OPR1000 was suitable for the operator action timing point in order to mitigate a severe accident.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :