Title of article
Determination of rupture frequency for feeders subject to flow accelerated corrosion
Author/Authors
Wang، نويسنده , , Min and Li، نويسنده , , Ming and Lehockey، نويسنده , , Edward and Duan، نويسنده , , Xinjian and Kozluk، نويسنده , , Michael J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
2234
To page
2239
Abstract
Feeder pipe wall thinning due to flow accelerated corrosion (FAC) has been identified as a degradation mechanism that may affect the operating life of outlet feeder pipes. A large number of feeders are expected to require costly repair or replacement over the remaining life of the station if a conservative FAC rate is used in the deterministic structural integrity assessment. The paper presents a preliminary probabilistic framework for determining the rupture frequency of feeders subject to FAC based on commercial probabilistic fracture mechanics code WinPRAISE 2007. The obtained information can be used as inputs for developing risk-informed feeder life management plans. Darlington Unit 2 is selected to demonstrate the proposed method.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2011
Journal title
Nuclear Engineering and Design Eslah
Record number
1590918
Link To Document