Computerized image analysis: Estimation of breast density on mammograms
Author/Authors
Zhou، Chuan نويسنده , , Chan، Heang-Ping نويسنده , , Petrick، Nicholas نويسنده , , Helvie، Mark A. نويسنده , , Goodsitt، Mitchell M. نويسنده , , Sahiner، Berkman نويسنده , , Hadjiiski، Lubomir M. نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2015
Pages
-1055
From page
1056
To page
0
Abstract
An automated image analysis tool is being developed for the estimation of mammographic breast density. This tool may be useful for risk estimation or for monitoring breast density change in prevention or intervention programs. In this preliminary study, a data set of 4-view mammograms from 65 patients was used to evaluate our approach. Breast density analysis was performed on the digitized mammograms in three stages. First, the breast region was segmented from the surrounding background by an automated breast boundary-tracking algorithm. Second, an adaptive dynamic range compression technique was applied to the breast image to reduce the range of the gray level distribution in the low frequency background and to enhance the differences in the characteristic features of the gray level histogram for breasts of different densities. Third, rule-based classification was used to classify the breast images into four classes according to the characteristic features of their gray level histogram. For each image, a gray level threshold was automatically determined to segment the dense tissue from the breast region. The area of segmented dense tissue as a percentage of the breast area was then estimated. To evaluate the performance of the algorithm, the computer segmentation results were compared to manual segmentation with interactive thresholding by five radiologists. A "true" percent dense area for each mammogram was obtained by averaging the manually segmented areas of the radiologists. We found that the histograms of 6% (8 CC and 8 MLO views) of the breast regions were misclassified by the computer, resulting in poor segmentation of the dense region. For the images with correct classification, the correlation between the computerestimated percent dense area and the "truth" was 0.94 and 0.91, respectively, for CC and MLO views, with a mean bias of less than 2%. The mean biases of the five radiologistsʹ visual estimates for the same images ranged from 0.1% to 11%. The results demonstrate the feasibility of estimating mammographic breast density using computer vision techniques and its potential to improve the accuracy and reproducibility of breast density estimation in comparison with the subjective visual assessment by radiologists.
Keywords
power quality , short circuit current , transient over voltage , Fault current limiter
Journal title
MEDICAL PHYSICS
Serial Year
2001
Journal title
MEDICAL PHYSICS
Record number
1592
Link To Document