Title of article :
Simulation of AP1000ʹs passive containment cooling with the German Containment Code System COCOSYS
Author/Authors :
Broxtermann، نويسنده , , Philipp and Allelein، نويسنده , , Hans-Josef، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
326
To page :
332
Abstract :
In this paper the applicability of the German containment code system COCOSYS to the simulation of AP1000ʹs passive containment cooling is presented. For this purpose calculation results of an adopted nodalisation from Westinghouseʹs WGOTHIC code and a nodalisation featuring a plume modelling are validated against experimental data of the large scale test facility. This facility is used to experimentally investigate AP1000ʹs passive containment cooling system. The gained experience helps to perform conservative and best estimate calculations of AP1000ʹs containment response during a large break loss of coolant accident. Results of the validation show reproducibility of WGOTHIC results with COCOSYS and good agreement of the calculated values using a plume nodalisation with the experimental values. The loss of coolant accident peak pressure of AP1000 containment conservatively calculated by COCOSYS only differs about 0.1–0.2 bar from results obtained by using the codes MELCOR and WGOTHIC. A best estimate calculation considering plumes above the compartments of the steam generators results in a peak pressure 0.8 bar lower than the WGOTHIC calculation. The performed validation shows the applicability of COCOSYS’ present heat transfer models to a new application field like the passive containment cooling. In consequence COCOSYS is able to deliver reasonable results for both conservative and best estimate AP1000 PCS calculations.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2013
Journal title :
Nuclear Engineering and Design Eslah
Record number :
1593466
Link To Document :
بازگشت