Title of article :
Feasibility research of containment venting for CANDU6
Author/Authors :
Huang، نويسنده , , Gaofeng and Fang، نويسنده , , Likai، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
8
From page :
113
To page :
120
Abstract :
After Fukushima accident, control strategy of containment integrity is evaluated for most nuclear power plants. Containment venting is deemed as one of the most important strategies to control containment integrity. However, for early CANDU6 design, there is no special containment venting system used for severe accidents. Feasibility of containment venting for CANDU6 is studied. Containment venting without filter and containment venting with filter are studied. In the method of containment venting without filter, D2O vapor recovery system is regarded as venting path. In the method of containment venting with filter, venturi filter is used. Mode of venting valve open and non-close, venting valve open and close are studied, in respectively. Study results indicate that containment venting is feasible for control containment integrity in severe accidents of CANDU6.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2014
Journal title :
Nuclear Engineering and Design Eslah
Record number :
1594067
Link To Document :
بازگشت