Title of article :
Safety evaluation of small-break LOCA with various locations and sizes for SMART adopting fully passive safety system using MARS code
Author/Authors :
Chun، نويسنده , , Ji-Han and Chung، نويسنده , , Bub-Dong and Lee، نويسنده , , Guy-Hyung and Bae، نويسنده , , Kyoo-Hwan and Kim، نويسنده , , Young-In and Chung، نويسنده , , Young-Jong and Kim، نويسنده , , Keung Koo Kim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
A safety evaluation of SMART adopting a fully passive safety system was performed for a small-break loss of coolant accident (SBLOCA) with various break locations and sizes using the MARS code. It is necessary for SMART, adopting a fully passive safety system composed of passive safety injection system (PSIS), automatic depressurization system (ADS), and passive residual heat removal system (PRHRS), to satisfy the passive safety performance requirements, i.e., the capability to maintain safe shutdown conditions for a minimum of 72 h without AC power supply or operator action in the case of a design basis accident. A number of SBLOCAs of different locations and sizes were analyzed using the MARS code. The results of the break spectrum analyses showed that the collapsed liquid level inside the core support barrel is maintained high enough above the top of the core owing to the sufficient passive safety injection flow from the core makeup tank (CMT) and safety injection tank (SIT). Therefore, the core is not uncovered for 72 h after the break without AC power supply or operator action, resulting in a continuous decrease of fuel cladding temperature throughout the transient.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah