Title of article :
Life cycle cost analysis of single slope hybrid (PV/T) active solar still
Author/Authors :
Kumar، نويسنده , , Shiv and Tiwari، نويسنده , , G.N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
10
From page :
1995
To page :
2004
Abstract :
This paper presents the life cycle cost analysis of the single slope passive and hybrid photovoltaic (PV/T) active solar stills, based on the annual performance at 0.05 m water depth. Effects of various parameters, namely interest rate, life of the system and the maintenance cost have been taken into account. The comparative cost of distilled water produced from passive solar still (Rs. 0.70/kg) is found to be less than hybrid (PV/T) active solar still (Rs. 1.93/kg) for 30 years life time of the systems. The payback periods of the passive and hybrid (PV/T) active solar still are estimated to be in the range of 1.1–6.2 years and 3.3–23.9 years, respectively, based on selling price of distilled water in the range of Rs. 10/kg to Rs. 2/kg. The energy payback time (EPBT) has been estimated as 2.9 and 4.7 years, respectively.
Keywords :
Life cycle cost analysis , Passive and hybrid (PV/T) active solar still , Energy payback period
Journal title :
Applied Energy
Serial Year :
2009
Journal title :
Applied Energy
Record number :
1603934
Link To Document :
بازگشت