• Title of article

    Evaluating the impact of canyon geometry and orientation on cooling loads in a high-mass building in a hot dry environment

  • Author/Authors

    Krüger، نويسنده , , E. and Pearlmutter، نويسنده , , D. and Rasia، نويسنده , , F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    11
  • From page
    2068
  • To page
    2078
  • Abstract
    In the present paper, thermal simulation software (IDA Indoor Climate and Energy, developed by EQUA, Sweden) was employed in order to evaluate the effect of different street canyon geometries and orientations on building cooling loads in a dry environment – Sede-Boqer, located in the Negev desert, Israel. A residential building was monitored from January to August 2006 to calibrate the thermal and energy simulations in summer, using diverse solar geometries and axis orientations as input data. Simulations were carried out using the local TMY, taking into account different aspect ratios (H/W): 0.33, 0.66, 1 and 2 and street axis orientations: east–west, north–south, northwest–southeast (parallel to prevailing wind) and northeast–southwest (perpendicular to prevailing wind). Results are shown in terms of energy consumption for cooling for each canyon configuration. From the obtained results, general recommendations can be traced for urban planning in arid regions, which could help promoting sustainable and energy-responsive buildings.
  • Keywords
    Urban canyons , Energy simulations , Canyon geometry
  • Journal title
    Applied Energy
  • Serial Year
    2010
  • Journal title
    Applied Energy
  • Record number

    1604245