• Title of article

    Absorption of nitric oxide from simulated flue gas using different absorbents at room temperature and atmospheric pressure

  • Author/Authors

    Yu، نويسنده , , Hesheng and Zhu، نويسنده , , Qunyi and Tan، نويسنده , , Zhongchao، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    6
  • From page
    53
  • To page
    58
  • Abstract
    Effective removal of nitrogen oxides (NOx) from flue gas allows more fossil fuels to be produced and utilized with less negative impact on the environment. It would be more cost-effective, however, if nitric oxide (NO) is oxidized to soluble nitrate and nitrite and then removed from the air by existing desulfurization wet scrubbers. This paper compares the effectiveness of three different oxidants for this purpose, namely, ethylenediaminetetraacetic acid; iron (2+) (Fe(II)–EDTA), hexamminecobalt(II) chloride ([Co(NH3)6]Cl2), and hydrogen peroxide (H2O2). Experimental results using column reactors showed that [Co(NH3)6]Cl2 was more effective over the same period of time. The best initial NO removal efficiency of about 96.45% was measured at the inlet flow rate of 500 ml/min; the temperature of approximately 19 °C; the pH value of around 10.5; and the concentrations of [Co(NH3)6]Cl2 , NO and O2 of 0.06 mol/L, 500 ppm and 5.0%, respectively.
  • Keywords
    ABSORPTION , Nitric oxide , Flue Gas
  • Journal title
    Applied Energy
  • Serial Year
    2012
  • Journal title
    Applied Energy
  • Record number