Title of article
Performance evaluation of solar aided feedwater heating of coal-fired power generation (SAFHCPG) system under different operating conditions
Author/Authors
Hong-juan، نويسنده , , Hou and Zhen-yue، نويسنده , , Yu and Yong-ping، نويسنده , , Yang and Si، نويسنده , , Chen and Na، نويسنده , , Luo and Junjie، نويسنده , , Wu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
9
From page
710
To page
718
Abstract
Integrating solar energy with a coal-fired power plant or other power systems has been proved to be an efficient way to utilize solar energy for power generation. Solar aided feedwater heating of a coal-fired power generation (SAFHCPG) system, which is mainly discussed in this paper, is chosen as an option for its easy operation and flexible control nature.
rformance of a SAFHCPG system at design point is analyzed under various load conditions in the paper. As the results show in Table 4, the lower load of coal-fired unit that solar aid, the lower solar-to-electric efficiency will be. For a SAFHCPG system, its performance is influenced by the solar radiation intensity and the electrical load demand on the grid side. The correlation between the annual performance of a SAFHCPG plant and the two key factors is discussed and then the optimal aperture area of solar field is derived. The result shows that, for the case studied the optimal aperture area of solar field and the lowest LEC (Levelized Electricity Costs) are: 115395 m2 and 0.472 ¥/kW h in a typical year; 138945 m2 and 1.010 ¥/kW h in an extremely low radiation year; 91845 m2 and 0.426 ¥/kW h in an extremely high radiation year respectively.
Keywords
Solar aided power generation , Feedwater heating , Annual performance
Journal title
Applied Energy
Serial Year
2013