Title of article
Thermal diffusion in the modified Frazier schemes with column heights varied at a constant increment for improved performance
Author/Authors
Yeh، نويسنده , , Ho-Ming and Tsai، نويسنده , , Zheng-Xiu and Hsu، نويسنده , , Ching Chun، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
8
From page
1241
To page
1248
Abstract
The effects of column number and column-height increment on the degree of separation in the modified Frazier scheme of thermal diffusion columns with the total sum of column heights fixed, has been investigated. The equations, which may be employed to predict the optimal column number and the optimal column-height increment for the maximum separation, have been derived. Considerable improvement in performance is obtainable if the column number and column-height increment in a modified Frazier scheme with the total sum of column heights fixed, are properly assigned under a certain flow-rate operation, instead of using the conventional Frazier scheme of constant column height with the same total sum of column heights.
Keywords
thermal diffusion , Increasing column height , Modified Frazier scheme
Journal title
Chemical Engineering and Processing: Process Intensification
Serial Year
2010
Journal title
Chemical Engineering and Processing: Process Intensification
Record number
1610471
Link To Document