Title of article :
GC–MS detection and quantification of lipopolysaccharides in polysaccharides through 3-O-acetyl fatty acid methyl esters
Author/Authors :
de Santana-Filho، نويسنده , , Arquimedes Paixمo and Noleto، نويسنده , , Guilhermina Rodrigues and Gorin، نويسنده , , Philip Albert James and de Souza، نويسنده , , Lauro Mera and Iacomini، نويسنده , , Marcello and Sassaki، نويسنده , , Guilherme Lanzi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
The most common method used to quantify lipopolysaccharide (LPS) in polysaccharide samples is the Limulus amebocyte lysate (LAL) test. It is a very sensitive and simple, although not accurate with samples containing carbohydrates, such as widely distributed (1 → 3)-linked β-glucans. Another method, the Polymyxin B assay, suffers interference with samples containing negatively charged polysaccharides. We have now developed a method to detect and quantify LPS in carbohydrate-containing samples, using GC–MS of derived acetylated 3-OH fatty acid methyl esters. The method proved to be robust, highly specific and sensitive, allowing detection of LPS at 1 ng, 100 times less than the amount of LPS frequently used as positive control in immunological experiments. In order to demonstrate the applicability of the method, 14 polysaccharide samples were analyzed. On two of them, the presence of LPS was detected at concentrations of 16.1 and 12.7 ng/300 μg polysaccharide.
Keywords :
LPS determination , GC–MS , Polysaccharides , Nitric oxide pathway , ?-glucan
Journal title :
CARBOHYDRATE POLYMERS
Journal title :
CARBOHYDRATE POLYMERS