Title of article :
Acoustic emission sources of breakdown failure due to pulsed-electric discharge in concrete
Author/Authors :
Kencanawati، نويسنده , , Ni Nyoman and Shigeishi، نويسنده , , Mitsuhiro، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
8
From page :
1691
To page :
1698
Abstract :
Acoustic emission (AE) technique is applied to locate existing breakdown failure in concrete. Damage was generated in a concrete sample applying 6.4 kJ energy of pulsed-electric discharge. Both AE parameter analysis and waveform analysis were carried out. From results of AE parameter analysis, AE sources associated with existing breakdown failure were identified in the compression test. Prior to location analysis, AE waveforms detected were de-noised by employing the wavelet transform. The area of breakdown failure in concrete is identified by the source location analysis of these de-noised AE waveforms. Five locations of breakdown failure are found in the concrete sample. Micro-cracks occur starting from the lower part of concrete sample and then spread randomly in entire concrete body.
Keywords :
Pulsed-electric discharge , Damaged concrete , AE parameter , De-noised AE signal
Journal title :
Construction and Building Materials
Serial Year :
2011
Journal title :
Construction and Building Materials
Record number :
1631267
Link To Document :
بازگشت